Helium
spectrometry
PRINCIPE
- Electrons, give out by the filament, ionize the molecules
inside the chamber.
- Ions produced are launched to the electrode.
- A magnetic field deviate ions He+ on the measure target
to create an electrical current proportional to the number
of He+ ions.
DIFFERENT
METHODS
- Global hard vacuum test.
- Spraying test.
- Sniffing test.
- Bombing test.
|
 |
Pressure
variance
PRINCIPE
- The piece to test and the reference
piece are simultaneously air pressurized.
- A differential manometer control the
pressure variance functions of the time.
- The sensitivity is function of the
volume and is formulated by the following relation : VdP/dt
avec dP/dt = 1Pa.s-1.
|
|
Bubble
test
PRINCIPE
- The piece is immersed in the water and air pressurized.
- The operator observe the air bubbles formation exit from
the possible leaks.
- This techniques, essentially visual, does not reach the
industrial quality standard.
|
|
|
File
|
Fil size
|
Lang.
|
56k
|
128k
|
512k/ADSL
|
|
| ce_fr.pdf |
3100ko
|
|
7'33"
|
3'06"
|
0'46"
|
Available
|
| ce_gb.pdf |
-
|
|
-
|
-
|
-
|
Unavailable
|
| ce_de.pdf |
2386ko
|
|
5'49"
|
2'23"
|
0'36
|
Available
|
|